Installation

TDB3108, WF3208 Terreon® 54" Circular

Installation Instructions continued . . .

D PLACE THE INFRARED MODULE ASSEMBLY ON TOP OF SPRAYHEAD. ROTATE UNTIL INFRARED MODULE LOCKS IN WITH TIE BAR. DROP TWO INFRARED MODULE WIRES DOWN TO VALVE ASSEMBLY.

NOTE! Skip to step E for units without soap.

FOR UNITS WITH SOAP OPTION, SLIDE THE SPACER AND SOAP DISPENSER OVER THE 1-1/2" PIPE.

POSITION THE UPPER TIE BAR SLIGHTLY BELOW THE MODULE (SEE FIGURE 8 INSET ON PREVIOUS PAGE) OR SOAP DISPENSER E (SEE FIGURE 9) AND FASTEN SECURELY TO VENT PIPE WITH SET SCREWS PROVIDED. SECURE TOP COVER TO TIE BAR WITH TWO

CAP SCREWS PROVIDED.

F

FOR B UNIT: INSTALL 1/2" NOMINAL COPPER TUBING SUPPLY LINES (PASS THEM THROUGH HOLES IN COVER DOWN

 

THROUGH SUPPORT COLUMN) AND CONNECT SUPPLY LINES TO STOPS USING SUITABLE FITTINGS.

UNIT WITH “B” DRAIN AND I.R. MODULE

SHOWN, ALSO AVAILABLE WITH “H” DRAIN

SOAP

 

 

 

 

 

 

 

 

TOP COVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISPENSER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPACER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INFRARED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULE

TIE BAR

 

 

 

 

 

 

 

 

 

 

ASSEMBLY

 

 

 

 

 

 

 

S50-344

 

 

 

 

 

 

 

 

 

 

 

 

 

SPRAYHEAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S05-054

 

 

 

 

 

 

 

 

 

 

 

 

SUPPORT TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(STD.) S57-005

 

 

 

 

 

 

 

 

 

 

 

 

(JUV.) S57-006

Figure 9

Bradley Corporation • 215-1187 Rev. N; EN 06-915B

4/6/2007

15