TDB3108, WF3208 Terreon® 54" Circular

Installation

5

Valve and tubing connections

NOTE: Flush supply lines before making connections. Do not apply pipe sealant to compression fittings.

CONNECT 1/2" DIA. TUBING TO TEE AND SOLENOID ASSEMBLY, TWO PLACES. THE MALE CONNECTOR

A (FIGURE 10B) FOR THE VALVE ASSEMBLY WILL REMAIN TIGHT AND LEAKPROOF WHEN TUBING IS CUT AND INSTALLED PROPERLY. FOLLOW THE PROCEDURES BELOW WHEN INSTALLING TUBING TO ENSURE THAT YOU ACHIEVE A LEAKPROOF SEAL.

USING A SHARP RAZOR, CUT TUBING SQUARELY AND REMOVE ANY BURRS. DO NOT PINCH OR CRUSH END OF TUBING.

LOOSEN NUT ON FITTING. MOISTEN END OF TUBE AND PUSH INTO FITTING UNTIL IT IS FIRMLY SEATED. TIGHTEN NUT TO SECURE TUBE TO FITTING (MAKE SURE NUT IS SECURELY TIGHTENED).

IF CONNECTOR LEAKS, RESEAT TUBING ACCORDING TO ABOVE PROCEDURE. IF LEAKING PERSISTS, REPLACE MALE CONNECTOR, OR CALL YOUR BRADLEY REPRESENTATIVE FOR ASSISTANCE.

B HANG VALVE ASSEMBLY ON PEDESTAL BRACKET (SEE FIGURE 11 ON PAGE 17). USE WIRE TIE TO SECURE VALVES.

NOTE! For “O” and “B” units (overhead supplies) Skip steps C through E

C CONNECT THE 1/2" NPT FEMALE END OF THE STOP/CHECK VALVES TO THE ROUGH-INS.

D ATTACH FLEXIBLE HOSING TO THERMOSTATIC MIXING VALVE, TWO PLACES.

E

INSERT THE FILTER WASHERS (PROVIDED) INTO THE SWIVEL NUT AT THE END OF THE SUPPLY HOSES AND CONNECT TO THE

 

STOP/CHECK VALVES.

1/2" DIA. TUBE

 

FROM SPRAYHEAD

 

 

TEE

 

 

269-764

 

1/2" DIA. TUBE

 

NUT

R68-600012

VOLUME CONTROL

S02-045

 

 

 

SOLENOID

 

 

ASSY.

 

TUBING

S08-055

 

 

 

MALE TUBE

FLEXIBLE

 

CONNECTOR

HOSE

 

 

FILTER WASHER

THERMOSTATIC

MIXING VALVE

 

ASSEMBLY

 

S67-597

 

STOP/CHECK

 

 

VALVE

 

 

Figure 10a

VALVE ASSEMBLY S50-369

Figure 10b

16

4/6/2007

Bradley Corporation • 215-1187 Rev. N; EN 06-915B

Page 16
Image 16
Bradley Smoker TDB3108 installation manual Valve and tubing connections