BSPP Generator

SPECIFICATIONS

Maximum Surge Watts

. .8,125 watts

Continuous Wattage Capacity

. .6,500 watts

Power Factor

. . . . . . . . .1.0

Rated Maximum Continuous AC Load Current:

At 120 Volts

. . .54.2 Amps

At 240 Volts

. . .27.1 Amps

Phase

. . . . .1–phase

Rated Frequency

. . . .60 Hertz

Fuel Tank Capacity

.7 U.S. gallons

Shipping Weight

. . . . .210 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Engine Maintenance

See engine owner’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Fuel Valve Maintenance

The fuel valve is equipped with a fuel sediment cup, screen, retaining ring and o-ring that need to be cleaned every

6 months or 100 hours (whichever occurs first).

1.Move fuel valve to “Off” position.

2.Remove sediment cup from fuel valve. Remove o-ring, retaining ring and screen from fuel valve (Figure 14).

Figure 14 — Fuel Valve Maintenance

Screen

Retaining Ring

O-ring

Sediment Cup

3.Wash sediment cup, o-ring, retaining ring, and screen in a nonflammable solvent. Dry them thoroughly.

16

Page 16
Image 16
Briggs & Stratton PRO6500 Specifications, General Maintenance Recommendations, Engine Maintenance, Generator Maintenance

PRO6500 specifications

Briggs & Stratton PRO6500 is a powerful portable generator designed for both home and professional use. Known for its durability and reliability, this generator stands out in the market due to its innovative features and advanced technologies that provide users with an efficient power solution.

One of the main highlights of the PRO6500 is its robust engine. It is equipped with a Briggs & Stratton OHV engine that delivers a strong performance, providing 6500 running watts and 8500 starting watts. This capacity makes it suitable for powering essential appliances during outages or for tools at job sites. The generator features a 7.5-gallon fuel tank, which allows for extended run times, typically around 12 hours at 50% load. This means less time spent refueling and more time enjoying uninterrupted power.

Another significant feature of the PRO6500 is its advanced Wave inverter technology, which produces clean and stable power. This makes it safe for sensitive electronics such as laptops, smartphones, and gaming consoles, ensuring that users can power their devices without fear of damage. The generator also includes a low-emission engine that meets EPA regulations, promoting environmentally friendly operation.

The PRO6500 is designed with convenience in mind. It features an easy-to-use control panel that includes multiple circuit breakers, a start switch, and multiple outlets, allowing users to safely connect various devices and appliances. The generator also has an electric start feature, which eliminates the hassle of manual starting. Just a push of a button is all it takes to get the generator up and running.

Portability is another strong aspect of the PRO6500. It is built with a rugged steel frame and heavy-duty wheels, giving it the ability to be easily transported to different locations, whether in your backyard, on a job site, or during camping trips. The folding handle also makes it simpler to move and store.

Safety features are integrated into the design of the PRO6500. It includes low oil and overload shutdown systems to prevent engine damage and enhance longevity. The generator also has a digital hour meter that keeps track of runtime, which aids users in maintaining proper service intervals.

In conclusion, the Briggs & Stratton PRO6500 is a versatile and powerful generator that offers significant benefits in terms of performance, convenience, and safety. Whether for home use or professional applications, it provides reliable power solutions that users can depend on in various situations.