BSPP Generator

Ground Fault Protection

This unit is equipped with a Ground Fault Circuit Interrupter (GFCI).This device meets applicable federal, state and local codes.

The GFCI protects against electrical shock that may be caused if your body becomes a path which electricity travels to reach ground.This could happen if you touch a “Live” appliance or wire, or are touching plumbing or other materials that connect to the ground.

2.If handle moves to center, reset circuit breaker by firmly moving handle to “Off” (down) position, then to “On” (up) position.

CAUTION

If circuit breaker does not reset properly:

DO NOT use generator.

Call a Briggs & Stratton Power Products service center.

When protected by a GFCI, one may still feel a shock, but the GFCI should cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury.

DANGER

Generator produces powerful voltage.

The GFCI will not protect you against the following situations: -Line-to-line shocks;

-Current overloads or line-to-line short circuits.

The fuse or circuit breaker at the control panel must provide such protection.

Test GFCI Circuit Breaker

Test your GFCI circuit breaker (Figure 12) every month, as follows:

Figure 12 — GFCI Circuit Breaker

1.While generator is running, push white “Test” button. The circuit breaker should trip (handle will move to approximate center position), which will disconnect power to outlets.

CAUTION

If circuit breaker does not trip:

DO NOT use generator.

Call a Briggs & Stratton Power Products service center.

During Generator Use

If circuit breaker trips during use, it usually indicates faulty electrical equipment or cords. However, test the circuit breaker as follows;

1.Disconnect loads, reset and test circuit breaker as described earlier. Let generator run without any loads for 1 minute.

CAUTION

If circuit breaker trips in the 1 minute period:

DO NOT use generator.

Call a Briggs & Stratton Power Products service center.

2.If circuit breaker tests correctly, the electrical equipment or extension cords may be faulty. Replace faulty electrical equipment and cords before further use.

CAUTION

If circuit breaker tests correctly:

Have qualified personnel check all electrical equipment and cords for any defects.

Replace electrical equipment and cords or take to a qualified repair center.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator or electrical loads.

14

Page 14
Image 14
Briggs & Stratton PRO6500 owner manual Ground Fault Protection, Test Gfci Circuit Breaker, During Generator Use

PRO6500 specifications

Briggs & Stratton PRO6500 is a powerful portable generator designed for both home and professional use. Known for its durability and reliability, this generator stands out in the market due to its innovative features and advanced technologies that provide users with an efficient power solution.

One of the main highlights of the PRO6500 is its robust engine. It is equipped with a Briggs & Stratton OHV engine that delivers a strong performance, providing 6500 running watts and 8500 starting watts. This capacity makes it suitable for powering essential appliances during outages or for tools at job sites. The generator features a 7.5-gallon fuel tank, which allows for extended run times, typically around 12 hours at 50% load. This means less time spent refueling and more time enjoying uninterrupted power.

Another significant feature of the PRO6500 is its advanced Wave inverter technology, which produces clean and stable power. This makes it safe for sensitive electronics such as laptops, smartphones, and gaming consoles, ensuring that users can power their devices without fear of damage. The generator also includes a low-emission engine that meets EPA regulations, promoting environmentally friendly operation.

The PRO6500 is designed with convenience in mind. It features an easy-to-use control panel that includes multiple circuit breakers, a start switch, and multiple outlets, allowing users to safely connect various devices and appliances. The generator also has an electric start feature, which eliminates the hassle of manual starting. Just a push of a button is all it takes to get the generator up and running.

Portability is another strong aspect of the PRO6500. It is built with a rugged steel frame and heavy-duty wheels, giving it the ability to be easily transported to different locations, whether in your backyard, on a job site, or during camping trips. The folding handle also makes it simpler to move and store.

Safety features are integrated into the design of the PRO6500. It includes low oil and overload shutdown systems to prevent engine damage and enhance longevity. The generator also has a digital hour meter that keeps track of runtime, which aids users in maintaining proper service intervals.

In conclusion, the Briggs & Stratton PRO6500 is a versatile and powerful generator that offers significant benefits in terms of performance, convenience, and safety. Whether for home use or professional applications, it provides reliable power solutions that users can depend on in various situations.