Side View
Firebox Front Panel
LP Gas Orifice
Gas Orifice Tool
Step 4
Remove screw from each burner "foot" using a screwdriver. Carefully lift each burner up and away from valve openings. Set aside for later use.
Step 5
Use the gas orifice tool to remove the LP brass orifice from main burner valves through the hole on the firebox front panel. Repeat this step for all main and side burner valves in your grill. The side burner valve orifice is under the side shelf.
Note: All orifices of the grill, except rotisserie, are double orifices type (LP gas and natural gas).You only remove the LP gas orifice tip.
CAUTION: Some parts may contain sharp edges. Wear protective gloves if necessary.
Step 6
Remove all the control knobs from the control panel and set aside for later use.
32