Sets the duration of the variable time delay element [i.e. the single stage delay and stage 2 of the two stage delay] in steps of 1 minute within the range
Table 1 - Delay Switch Settings
Delay | S/W 2/2 | S/W 2/3 | S/W 2/4 | S/W 2/5 |
Duration |
|
|
|
|
|
|
|
|
|
Delay | Off | Off | Off | Off |
disabled |
|
|
|
|
|
|
|
|
|
1 min | On | Off | Off | Off |
|
|
|
|
|
2 min | Off | On | Off | Off |
|
|
|
|
|
3 min | On | On | Off | Off |
|
|
|
|
|
4 min | Off | Off | On | Off |
|
|
|
|
|
5 min | On | Off | On | Off |
|
|
|
|
|
6 min | Off | On | On | Off |
|
|
|
|
|
7 min | On | On | On | Off |
|
|
|
|
|
8 min | Off | Off | Off | On |
|
|
|
|
|
9 min | On | Off | Off | On |
|
|
|
|
|
10 min | Off | On | Off | On |
|
|
|
|
|
10 min | On | On | Off | On |
|
|
|
|
|
10 min | Off | Off | On | On |
|
|
|
|
|
10 min | On | Off | On | On |
|
|
|
|
|
10 min | Off | On | On | On |
|
|
|
|
|
10 min | On | On | On | On |
|
|
|
|
|
●SW 2/6 - Enable Zonal Alarms:
Select the type of sounder alarm response to a fire condition in conjunction with the Pulse Non Alarm Zones switch described below. [Not EN54 compliant function. Provided to meet existing customer requirements] :
○OFF: General Alarm Mode – all sounders operate continuously until silenced.
○ON: Zonal Sounder Mode - Sounder groups for zones not in the alarm condition may be selected, via the Pulse Non Alarm Zones switch [SW 2/7], to pulse or not to operate.
Note: Zonal alarms on the 2/4 zone panel affects the standard sounder circuits on the motherboard. On the 8, 16 and 32 zone panels, it affects only the [future] expansion module sounder circuits.
●SW 2/7- Pulse Non Alarm Zones:
Select the type of zonal sounder alarm response to a fire condition in conjunction with the Zone Alarms switch [SW 2/6] described above. [Not EN54 compliant function. Provided to meet existing customer requirements]:
With the Zone Alarms switch [SW 2/6] in the On position [Zonal Sounder Mode]:
○SW2/7 OFF: Zonal sounders for zone in the fire condition operate continuously until silenced. All others are silent.
○SW2/7 ON: Zonal sounders operate continuously - all other sounders operate in pulsed mode until silenced.