ROUTINE MAINTENANCE 5 - 15
5
Put the new fusing unit into the printer. Be sure to insert the fusing unit completely into the printer.
Figure 5-17
6
Secure the fusing unit with the two lock levers that are on both sides of the fusing unit.
Figure 5-18
7
Move the fusing unit pressure release levers to the Set position.
Figure 5-19
8
Close the back cover.
9
Turn the printer power switch back on.
10
Press any of the Menu buttons (+, –, Set or Back) to take the printer off line.
11
Press + or – until RESET MENU appears.
12
Press Set to proceed to the next menu level, and then press + or – until PARTS LIFE appears.
13
Press Set, and then press + until FUSER UNIT appears.
14
Press Set. The printer is now in the READY state.
Please be careful when replacing the fusing unit. Do not put pressure on the fusing unit; it should
go in easily. If it does not, make sure the fusing unit connector is free to move.
Do not apply force! It could damage both the fusing unit and the printer.