GETTING READY ——————————————————————————————————————————————————————————
24
Setting Up the Machine
The procedures for setting up the machine are described below. If the machine is not set up correctly, it may
shake or produce loud noises and the embroidery will not be sewn correctly. An optional sewing stand is
also available.

Setup and transporting precautions

CAUTION
The temperature of the operating environment should be between 5 °C (40 °F) and 40 °C
(104 °F). If the machine is operated in an environment that is either too cold or too hot,
the machine may malfunction.
Do not use the machine in a location where it will be exposed to dir ect sunlight,
otherwise the machine may malfunction.
Set up the machine with it’s four adjustable feet completely in cont act with the desk or
table, so that the machine is level.
Do not put anything under the embroidery machine that could block the ventilation slots
found on the rear underside of the machine, in order to avoid the possibility of the
machine’s motor overheating, resulting in a fire or in damage to t he machine.
The machine weight is approximately 37 kg (81 lb). The transporting or setting up of the
embroidery machine should be performed by two people.
When transporting the machine, be sure to lift it from the bottom at the indicated
positions by two people. Lifting the machine fro m any other area may damage the
machine or result in the machine falling, which could cause inju ries.
When lightning occurs, turn off the machine and unplug the power suppl y cord. Lightning
may cause the machine to malfunction.
Do not plug in the power supply cord until setup of the machine is completed, otherwise
injuries may result if the start/stop button is accident ally pressed and the machine starts
sewing.
When lubricating the machine, wear protective eyeglasses and gloves to prevent the oil or
grease from getting into your eyes or on your skin. Do not put the oil or grease into your
mouth. Keep the oil and grease out of the reach of children.