Troubleshooting and routine maintenance
121
B
ePut the print sample in front of the drum
unit, and find the exact position of the
poor print.
fTurn the drum unit gear by hand while
looking at the surface of the OPC
drum (1).
gWhen you have found the mark on the
drum that matches the print sample,
wipe the surface of the OPC drum with a
dry cotton swab until the dust or glue on
the surface comes off.
CAUTION
The drum is photosensitive so DO NOT
touch it with your fingers.
DO NOT clean the surface of the
photosensitive drum with a sharp object.
DO NOT use excessive force when
cleaning the drum unit.
hPut the toner cartridge back into the
drum unit until you hear it lock into place.
If you put the cartridge in correctly, the
green lock lever will lift automatically.
iPut the drum unit and toner cartridge
assembly back in the machine.
jClose the front cover.
kPlug the machine’s power cord back into
the electrical socket first, and then
reconnect all cables and telephone line
cord. Turn on the machine.
1