S-7200C
4. FUNCTION SETTINGS (G50 OPERATION PANEL)
8
4-5. Memory switch setting method (Standard) NOTE:
・ This cannot be set if DIP switch 1 has been set to ON, so set it to OFF.
・ If the LOCK key icon (1) is on, release the lock before carrying out the following
operations.
・
If the MAX key icon (2) is on, press the MAX key to return the main display to stitch
number display (orange).
1
Change to memory switch mode
2
Select a memory switch number (A)
3
Change the setting details (B).
4
The setting for the memory switch will be stored and (B) will stop
flashing and illuminate steadily.
NOTE:
The changed settings will be enabled after memory switch mode
has been exited.
5
Repeat steps 2 to 4 above to change other memory switch settings.
6
The memory switch number (A) and the setting
details (B) for that number will be displayed in
green in the main display (3).
NOTE:
If the current setting value is different from
the initial value, it will be displayed in
yellow.
* If you press the or key (4) at this time, only the memory switch
numbers with a current value that is different from the initial value will
be displayed in yellow.
Normal sewing machine operation will then be possible.
4192M
* If you would like to return the setting which is currently being displayed
to the default value, press the key.
*
If the setting details for the memory switch are different from the
original setting details, the setting details (B) will flash.
* If the setting details for the memory switch are different from the initial
values, they will be displayed in yellow.
2007B
2008B
2009B 2093B 2138M 2139M
4193M
2011B 4173M