S-7200C
4.
FUNCTION SETTINGS (G50 OPERATION PANEL)
29
-10. Output checking method
This is used at the following times.
When there is a problem with the operation panel PCB
When there is a problem with the drive mechanism
When you would like to check for broken codes.
You can check whether the signals being output by the CPU are driving the mechanisms correctly.
1
Change to output check mode
(While pressing the key, press the power ON switch.)
2
Select the item number (A)
3
4
[To check another item]
Return the treadle to the neutral position, and then repeat the operations in steps 2 and 3 above
.
5
[To return to the normal sewing machine starting condition]
Press the power OFF switch to turn off the power, and then turn the power back on.
The operation corresponding to the item number being checked will be carried out.
The item number (A) and the output
status (B) will appear in the main
display (1) in orange.
2159M
2031B 2139M
2036B 2097B
(Item number)
(Item name)
* If 2 seconds pass without no operations having been carried out,
the four characters on the left side of the main display will
alternately display the item number and the item name.