580J

MODEL NUMBER NOMENCLATURE

 

 

 

1

 

2

3

 

4

5

6

7

8

9

10

11

12

13

14

 

15

16

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

8

0

J

E

0

6

A

0

7

2

A

1

A

0

A

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

____________

 

 

______

 

 

________

 

 

 

 

 

 

 

______

 

 

 

 

 

 

 

Unit Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packaging

580J = Cooling/Gas Heat RTU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Standard

Legacy Series w/Puron Refrigerant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = LTL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Installed Options

E = 460--- 3---

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0A = None

 

 

J = 208/230---

1---

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P = 208/230---

3---

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intake/Exhaust Options

T = 575---3---

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = Temp econo w/ baro relief

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E = Temp econo w/ baro relief & CO2

04 = 3 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H = Enthalpy econo w/ baro relief

05 = 4 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L = Enthalpy econo w/ baro relief & CO2

06 = 5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q = Motorized 2 pos damper

07 = 6 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08 = 7.5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Fan Options

 

 

09 = 8.5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = Standard static option

12 = 10 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = Medium static option

14 = 12.5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 = High static option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrig. System/Gas Heat Options

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil Options

 

 

 

 

 

 

 

 

 

A = Standard 1--- Stage Cooling models/Nat gas heat

 

 

 

 

 

 

 

Models w/Round Tube Plate Fin (RTPF) condenser coil

B = Standard 1--- Stage Cooling models/Low NOx heat

 

 

 

 

 

 

 

(Outdoor ---

Indoor

---

Hail Guard)

C = Standard 1--- Stage Cooling models/SS HX

 

 

 

 

 

 

 

 

 

 

A = Al/Cu ---

Al/Cu

 

 

 

 

 

 

 

D = 2--- Stage Cooling models 08

---

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = Precoat Al/Cu

---

Al/Cu

 

 

F = 2--- Stage Cooling models and SS HX

 

 

 

 

 

 

 

 

 

 

 

 

 

C = E

--- coat Al/Cu

---

Al/Cu

 

 

G = 1--- Stage Cooling/Al HX w/Perfect Humidity 04---

07

 

 

 

 

 

 

 

D = E coat Al/Cu---

---

E

---

coat Al/Cu

H = 1--- Stage Cooling/Low NOx w/Perfect Humidity 04 07---

 

 

 

 

 

 

 

E = Cu/Cu

---

Al/Cu

 

 

 

 

 

 

J = 1--- Stage Cooling/SS HX w/Perfect Humidity 04---

07

 

 

 

 

 

 

 

F = Cu/Cu

---

Cu/Cu

 

 

 

 

K = 2--- Stage Cooling/Al Gas HX w/Perfect Humidity 08-14

 

 

 

 

 

 

 

M = Al/Cu ---

Al/Cu

---

Louvered Hail guards

M = 2--- Stage Cool/SS Gas HX w/Perfect Humidity 08-14

 

 

 

 

 

 

 

N = Precoat Al/Cu

---

Al/Cu

--- Louvered Hail Guards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P = E coat Al/Cu

 

Al/Cu

Louvered Hail Guards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q = E coat Al/Cu ---

E coat Al/Cu --- Louvered Hail Guards

Standard/Stainless Steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R = Cu/Cu

---

Al/Cu

---

Louvered Hail Guards

072

= 72,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Cu/Cu

---

Cu/Cu ---

Louvered Hail Guards

115

= 115,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models w/All aluminum, Novation condenser coils

125

= 125,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Outdoor ---

Indoor

---

Hail Guard)

150

= 150,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G = Al/Al ---

Al/ Cu

 

 

 

 

 

 

 

180

= 180,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H = Al/Al ---

Cu/Cu

 

 

 

 

 

 

 

224

= 224,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J = Al/Al ---

E coat Al/Cu

 

 

250

= 250,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K = E coat Al/Al ---

Al/ Cu

 

 

Low NOx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L = E coat Al/Al ---

E coat Al/Cu

060

= 60,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Al/Al ---

Al/Cu ---

Louvered Hail Guards

090

= 90,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U = Al/Al ---

Cu/ Cu, Louvered Hail Guards

120

= 120,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V = Al/Al ---

E coat Al/Cu, Louvered Hail Guards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W = E coat Al/Al

 

Al/ Cu, Louvered Hail Guards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = E coat Al/Al ---

E coat Al/Cu, Louvered Hail Guards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Page 4
Image 4
Bryant 580J manual Unit Type Packaging, Voltage Factory Installed Options, Intake/Exhaust Options, Cooling Tons, Heat Level