Bryant manual Features/Benefits, Model Number Nomenclature, 582A N, W 024 040 A A A D

Models: 582A

1 24
Download 24 pages 11.98 Kb
Page 2
Image 2
FEATURES/BENEFITS

FEATURES/BENEFITS

Low Sound Ratings ensure a quiet indoor and outdoor environ- ment with sound ratings as low as 7.5 bels. (See ARI capacity charts for individual values.)

Easy-to-Service Cabinets provide easy single-panel acces- sibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with or without a mounting pad. Convenient handholds are provided to manipulate the unit on the jobsite. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4-in. wide perimeter flange makes frame mounting on a roof- top easy.

Downflow Operation unit is easily converted for downflow in the field to allow vertical ductwork connections. The basepan uti- lizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode.

Integrated Gas Control Board provides safe and efficient con- trol of heating and simplifies troubleshooting with built-in diag- nostic function.

Cabinets are constructed of heavy-duty, phosphated, zinc- coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator/heat exchanger compartment are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refriger- ation and Air Conditioning Engineers [ASHRAE] No. 62P.) The sloped drain pan minimizes standing water in the drain. An ex- ternal drain is provided.

 

 

 

 

 

 

 

MODEL NUMBER NOMENCLATURE

582A N

W 024 040 A A A D

Model Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor (Not an Option)

582A – Single Package

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D – 1/4 HP Motor

Gas/Electric Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F – 1/2 HP Motor

Electric Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G – 3/4 HP Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J208-230-1-60*

N 208/230-1-60

Options

P 208/230-3-60

- -

– Wire Grille

E 460-3-60

HD – Louvered Grille

Fuel and Controls

JT – Louvered Grille and Vinyl-

 

Coated Condenser Coil Fin

W — Natural Gas

 

KT – Wire Grille and Vinyl-Coated Condenser Coil Fin

P — Propane Gas

LC – Louvered Grille, AL Evaporator and CU

 

 

 

Nominal Cooling Capacity

 

Condenser Coil

018 – 1.5 Tons

MU – Louvered Grille, CU Evaporator and CU

024 – 2.0 Tons

 

Condenser Coils

030 – 2.5 Tons

NC – Wire Grille, AL Evaporator and CU Condenser Coil

036 – 3.0 Tons

PU – Wire Grille, CU Evaporator and CU Condenser Coils

042 – 3.5 Tons

 

 

048 – 4.0 Tons

 

 

060 – 5.0 Tons

Series

 

 

 

 

 

 

A

Original

 

 

 

Low NOx:

 

 

 

A

Std. Unit

 

 

 

N – Low NOx unit

 

 

 

Heat Input Size (Btuh)

 

 

 

040 – 40,000

 

 

 

060 – 60,000

 

LEGEND

090 – 90,000

 

115 – 115,000

AL

Aluminum

130 – 130,000

CU

Copper

 

 

*Minimum voltage of 197 at maximum load conditions (048 size only).

2

Page 2
Image 2
Bryant manual Features/Benefits, Model Number Nomenclature, 582A N, W 024 040 A A A D