TABLE 7ÐICM FIOP PHYSICAL DATAÐUNIT 702B

THIS DATA APPLIES TO 702B UNITS WITH THE ICM INDOOR MOTOR FIOP

UNIT SIZE

024

030

036

042

048

060

NOMINAL CAPACITY (ton)

2

2-1/2

3

3-1/2

4

5

OPERATING WEIGHT (lb)

270

291

299

321

326

399

COMPRESSOR

 

 

Scroll

 

 

REFRIGERANT (R-410A)

5.0

5.5

6.9

9.0

9.5

10.0

Quantity (lb)

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

Check-Flo-Rater™ Piston

 

 

Orifice ID (in.)

.057

.057

.065

.070

.073

.086

CONDENSER COIL

1...17

1...17

2...17

2...17

2...17

2...17

Rows...Fins/in.

10.9

12.7

9.1

12.3

12.3

16.4

Face Area (sq. ft.)

 

 

 

 

 

 

CONDENSER FAN

2350

2350

2350

2350

3300

3300

Nominal Cfm

22

22

22

22

22

22

Diameter (in.)

1/8 (825)

1/8 (825)

1/8 (825)

1/8 (825)

1/4 (1100)

1/4 (1100)

Motor Hp (Rpm)

 

 

 

 

 

 

EVAPORATOR COIL

3...15

3...15

3...15

3...15

4...15

4...15

Rows...Fins/in.

3.7

3.7

3.7

4.7

4.7

4.7

Face Area (sq. ft.)

 

 

 

 

 

 

EVAPORATOR BLOWER

800

1000

1200

1400

1600

2000

Nominal Airflow (Cfm)

10x10

10x10

10x10

11x10

11x10

11x10

Size (in.)

1/2

1/2

3/4

3/4

3/4

1

Motor (HP)

 

 

 

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

610 ± 15

 

 

Cutout

 

 

 

 

 

 

420 ± 25

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

 

LOSS-OF-CHARGE/LOW-PRESSURE SWITCH

 

 

 

 

 

 

(Liquid Line) (psig)

 

 

20 ± 5

 

 

Cutout

 

 

45 ± 10

 

 

Reset (Auto)

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20 X 20 X 1

20 X 20 X 1

20 X 24 X 1

24 X 30 X 1

24 X 30 X 1

24 X 30 X 1

Throwaway

 

 

 

 

 

 

Ð18Ð

Page 18
Image 18
Bryant 683B, 583B, 602B installation instructions ÐICM FIOP PHYSICAL DATAÐUNIT 702B, Ð18Ð

602B, 683B, 702B, 583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.