TABLE 14Ð583B & 683B GAS HEATING ICM AIRFLOW

LARGE CABINET

 

EASY SELECT™

1000

1250

1600

1750

1800

BOARD SETTING (CFM)

 

 

 

 

 

 

 

External

 

 

 

 

 

Unit

 

Static

0.0±1.0

0.0±1.0

0.0±1.0

0.0±1.0

0.0±1.0

Size

 

Pressure

 

 

 

 

 

 

 

 

Gas Heat Size

 

 

 

 

 

042

 

060

1000

±

±

±

±

 

090

±

1250

±

±

±

 

 

 

 

090

±

1250

±

±

±

048

 

115

±

±

1600

±

±

 

 

130

±

±

±

1750

±

 

 

090

±

1250

±

±

±

060

 

115

±

±

1600

±

±

 

 

130

±

±

±

±

1800

TABLE 15Ð583B & 683B ICM AIR FLOW VS. TEMPERATURE RISE CHART

 

COOLING

RATED GAS

AIRFLOW SETTING

CALCULATED

MIN.

MAX

MAX

UNIT

INPUT RATE

EASY SELECT™

TEMPERATURE

TEMP

TEMP

DISCH.

SIZE

 

(X 1000)

(SCFM)

RISE

RISE

RISE

TEMP

 

 

 

 

40

800

36.5

20

50

175

 

024

 

 

 

 

 

 

 

60

1100

40

35

65

165

 

 

(583B Only)

 

 

 

 

 

 

 

 

030

40

800

36.5

20

50

175

 

 

 

 

 

 

 

 

60

1100

40

35

65

165

 

 

 

 

 

 

 

 

 

 

 

036

60

1100

40

25

55

165

 

 

 

 

 

 

 

583B

90

1200

54

45

75

175

 

 

 

 

 

 

 

 

&

042

60

1000

44

20

50

165

683B

90

1250

53

35

65

170

 

 

 

 

 

 

 

 

 

 

 

90

1250

53

25

55

165

 

 

 

 

 

 

 

 

 

048

115

1600

53

35

65

170

 

 

130

1750

54

40

70

175

 

 

90

1600

41

25

55

155

 

060

115

1600

53

35

65

170

 

 

130

1800

53

40

70

175

 

 

 

 

 

 

 

 

TABLE 16Ð702B/602B COOLING & HEATING DRY COIL ICM AIRFLOW

SMALL CABINET

 

CFM ADJUST

 

LO PIN

 

 

NOM PIN

 

 

HI PIN

 

UNIT

PIN SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZE

EXTERNAL STATIC

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

0.0±0.4

0.4±0.7

0.7±1.0

 

PRESSURE RANGE

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

800

725

±

885

805

730

990

930

855

024

COOLING

715

670

±

715

695

645

795

775

745

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

720

660

±

790

745

685

890

850

785

 

COMFORT (602B Only)

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

1010

920

825

1105

1030

930

1255

1160

1050

030

COOLING

890

845

795

890

865

825

1010

980

925

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

945

850

765

1020

965

895

1140

1105

995

 

COMFORT (602B Only)

 

 

 

 

 

 

 

 

 

 

 

COOLING ²

1110

1025

970

1235

1175

1115

1400

1355

1280

 

 

 

 

 

 

 

 

 

 

 

036

COOLING

990

960

910

990

975

940

1125

1110

1085

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

HEAT PUMP

1035

975

910

1160

1080

1020

1305

1275

1220

 

COMFORT (602B Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

² Heat Pump Efficiency and Cooling pin selections deliver equal airflow

 

 

 

 

 

 

 

Ð25Ð

Page 25
Image 25
Bryant 702B Ð583B & 683B GAS HEATING ICM AIRFLOW LARGE CABINET, Ð583B & 683B ICM AIR FLOW VS. TEMPERATURE RISE CHART, Ð25Ð

602B, 683B, 702B, 583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.