Bryant GT-PG (50YE) manual Discharge Connection Return Connection

Models: GT-PG (50YE)

1 48
Download 48 pages 63.8 Kb
Page 30
Image 30

GT-PG (50YE) Series

Dimensions — Vertical Upflow GT-PG (50YE) Series

 

 

 

 

Discharge Connection

 

 

 

Return Connection

 

 

 

 

 

 

 

 

Standard Deluxe Filter Rack

 

 

Vertical

 

Duct Flange Installed (+/- 0.20 in, +/- 5.1mm)

 

 

 

 

 

(+/- 0.20 in, +/- 5.1mm)

 

 

Upflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

O

P

Q

 

 

S

 

T

 

 

 

Model

 

 

 

 

 

 

 

 

 

Left

N

Supply

Supply

Right

R

 

Return

 

Return

 

U

 

 

 

 

 

 

 

 

 

 

 

Return

 

Width

Depth

Return

 

 

Depth

 

Height

 

 

 

018

 

in

7.2

5.8

14.0

14.0

4.9

1.7

 

22.2

 

22.2

 

1.7

 

 

cm

18.3

14.8

35.6

35.6

12.4

4.3

 

56.4

 

66.5

 

4.3

 

 

 

 

 

 

 

024 -

 

in

7.2

5.8

14.0

14.0

4.9

1.7

 

22.2

 

26.2

 

1.7

 

030

 

cm

18.3

14.8

35.6

35.6

12.4

4.3

 

56.4

 

66.5

 

4.3

 

036

 

in

6.4

6.3

18.0

18.0

5.3

1.7

 

27.2

 

26.2

 

1.7

 

 

cm

16.1

16.0

45.7

45.7

13.5

4.3

 

69.1

 

66.5

 

4.3

 

 

 

 

 

 

 

042 -

 

in

6.4

6.3

18.0

18.0

5.3

1.7

 

27.2

 

30.2

 

1.7

 

048

 

cm

16.1

16.0

45.7

45.7

13.5

4.3

 

69.1

 

76.7

 

4.3

 

060 -

 

in

6.4

6.3

18.0

18.0

5.3

1.7

 

27.2

 

34.2

 

1.7

 

070

 

cm

16.1

16.0

45.7

45.7

13.5

4.3

 

69.1

 

86.9

 

4.3

 

 

 

 

 

 

 

 

 

 

 

 

Field Installed

Access Panels

 

 

 

 

 

 

 

 

 

 

 

Discharge Flange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deluxe Filter Bracket

 

 

 

 

 

Legend

CAP=Control Access Panel

CSP=Compressor Service Panel

BSP=Blower Service Panel

ASP=Alternate Service Panel

 

P

N

 

B

 

N

P

O

Front

 

 

 

 

 

 

 

Q

Air Coil Side

 

Frame Depth

Air Coil Side

 

 

 

 

 

 

 

2 & 1 / 8" [54.0mm]

 

Front

Air Coil

O

A

CSP

M

BSP

CAP

ASP

ASP

2' (61cm) Optional Service Access Left Rtn

(right

Opposite)

Top View-Right Return

Flange Depth

Top View-Left Return

 

3 / 8" [9.5mm]

 

S

U

T

R

R

S

 

 

2' (61cm)

 

 

Service

 

U

 

 

Air Coil

Air Coil

 

T

 

Isometric

View

1.00 [25.4 mm]

C

ASP

Front

 

C

Power Supply

 

 

 

 

3 / 4" [19.1mm]

 

 

HV Knockout

 

 

1 / 2" [12.7mm]

 

 

Knockout

 

1.18 [30.0 mm]

Low Voltage

 

CSP

1 / 2" [12.7mm]

 

LV Knockout

 

 

 

 

CSP

Back

Back

Front

1.63

[41.4 mm] CAP

J K L

1.68 [42.7 mm]

Condensate - 3 / 4" Glue (PVC Socket)

(Opposite side of air coil)

4

3

2

F G

5

1

D H E

Right Return Right View

Left Return Left View

- Filter Rack Knife Edge

- Filter Rack Knife Edge

Front-View

Rev.: 08/9/12B

GT-PG

Bryant: Whatever it Takes.

30

 

 

 

Page 30
Image 30
Bryant GT-PG (50YE) manual Discharge Connection Return Connection

GT-PG (50YE) specifications

The Bryant GT-PG (50YE) is a state-of-the-art gas-fired packaged unit ideal for both commercial and residential applications. Renowned for its efficiency and reliability, this model stands out in the competitive HVAC market. With its sleek design and advanced features, it promises optimal performance while maintaining energy efficiency, making it a favorite among building owners and contractors alike.

One of the most remarkable features of the Bryant GT-PG (50YE) is its high-efficiency gas heat exchanger. This component enhances energy transfer, ensuring that maximum heat is produced with minimal energy consumption. With an Annual Fuel Utilization Efficiency (AFUE) rating that meets and exceeds industry standards, users can count on significant savings in energy bills over time. Additionally, the unit is equipped with a multi-speed blower that further enhances its efficiency by providing a consistent flow of air while reducing noise levels.

Another significant characteristic of the GT-PG (50YE) is its advanced control system. Featuring a user-friendly interface, this system allows for precise temperature control and integration with smart home technologies. The modulating gas valve optimizes performance based on heating demand, providing customized comfort for any environment.

Reliability is key with the Bryant GT-PG (50YE). It is built with sturdy materials designed to withstand the elements, enhancing its lifespan and reducing maintenance needs. The inclusion of a robust stainless steel heat exchanger aids in preventing corrosion, ensuring durability in various climates.

Moreover, safety features are paramount in the design of the GT-PG (50YE). It includes integrated safety controls, such as a flame rollout switch and limit control, providing peace of mind for users.

Installation and maintenance are made easy with this model, which includes a compact design allowing for versatile placement options. Service access has been thoughtfully designed, ensuring technicians can perform routine maintenance without hassle.

In conclusion, the Bryant GT-PG (50YE) is a powerhouse of an HVAC solution, blending efficiency, reliability, and advanced technology. With its exceptional heating capabilities, user-friendly controls, and durable construction, this model is perfect for anyone looking to invest in long-term comfort and performance. Whether for residential or commercial use, the GT-PG reflects Bryant's commitment to quality and customer satisfaction.