DAILY CLEANING
SPRAYHEAD REMOVAL
1
Clean & inspect parts daily.
Replace if loose, cracked or damaged.
2
3.
Lift handle. Remove brew chamber and cup. Wipe down sprayhead with a soft cloth to remove any residue. Once a month, or as use necessitates, rotate sprayhead coun- terclockwise and remove as illustrated.
Clean & lube guides as needed.
Thoroughly wash sprayhead, cup and check valve (with mild soap and water) and rinse with fresh water. Wipe out the cap area above sprayhead and around
CHECK VALVE REMOVAL
After cleaning, apply very light film of silicon lube (included) to
Push the check valve up from underneath the cup support.
4
STOP!
DO NOT LUBE
THIS
Thoroughly flush the check valve while pushing the center poppet open with a probe.
Page 10 | 42822.1 110411 |
|