ADVANCED ADJUSTMENTS & OPTIONAL SETTINGS
TankHeater RELAY
(7) ON NEXT OFF
TankHeater TRIAC
(8) ON NEXT OFF
B | TEST SWITCHES | |
NO | YES | |
|
|
|
Allows testing of the membrane switches & brew chamber safety switch. Press "YES" to enter test mode. Display will read "PRESS PROGRAM TO EXIT" then change to "NOTH-
ING PRESSED".
(1)
NOTHING PRESSED
Display will show when a button is pressed.
Opening/closing the brew chamber during the "TEST SWITCHES" mode will display the status of the safety switch.
(2)
BREW CHAMBER IN
OUT = open IN = closed
Press the "PROGRAM" button to exit.
C | CALIBRATE FLOW ? | |
NO | YES | |
|
|
|
Skip to "CAL TEMPERATURE
SENSOR"
(1) | !!! CAUTION !!!! |
| |
|
|
|
|
(2) | CONTAINER MUST |
HOLD 10 OUNCES | |
|
|
|
|
(3) | PRESS |
BREW TO START | |
|
|
Use of this test allows user to "tell" the brew exactly how many ounces are collected during a 10 second "test" brew mode.
Use a measuring container that will hold at least 10 ounces. Place container in position on drip tray.
Press "BREW" button to start.
Page 18 | 42822.1 072810 |
|