FRONT PANEL REMOVAL AND TANK DRAINING
WARNING: DISCONNECT BREWER FROM POWER SOURCE BEFORE PANEL REMOVAL.
Remove drip tray. Remove two screws. Lower the panel as far as it will go.
Push the top down to clear the brew cham- ber support arm, then pull the top out first.
TANK DRAINING | RESET TO FIRST TIME SETUP | ||
|
|
|
|
|
|
|
|
DISCONNECT BREWER
FROM WATER SUPPLY
BEFORE DRAINING
Pull drain hose out as shown. Slide clamp back and remove plug. Refer to program- ming section and enter "Factory Blowout" mode. Allow tank to drain into sink or suitable container.
NOTE: If tank was drained, follow this procedure before connecting brewer to power source. Disconnect brewer from power source. Connect to water supply. Install brew cup & chamber. Push and hold both arrow buttons while plugging in the brewer. When display reads "SET TO FIRST TIME UP", release arrow buttons. Place a minimum 40 oz. container under brew chamber. Press brew start button to begin cycle. If tank was empty, it will expel only 20 oz. If tank was still full, it will expel 40 oz.
Page 12 | 42822.1 040810 |
|