Bunn CDBCF APS-DV, CDBCF-DV, CDBC APS-DV, CDBC-MV, CDBC-DV, CDBCF-MV SERVICE cont LIMIT THERMOSTAT

Models: CDBCF-MV CDBCF APS-DV CDBCF APS-MV CDBC-DV CDBC-MV CDBC APS-DV CDBCF-DV

1 37
Download 37 pages 654 b
Page 26
Image 26
SERVICE (cont.)

SERVICE (cont.)

LIMIT THERMOSTAT

P1854

FIG. 6 LIMIT THERMOSTAT

Location:

The limit thermostat is located inside the front access panel on the front side of the tank.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Disconnect the blue and black wires from the limit thermostat.

3.With an ohmmeter, check for continuity across the limit thermostat terminals.

If continuity is present as described, the limit thermo- stat is operating properly.

If continuity is not present as described, replace the limit thermostat.

Removal and Replacement:

1.Remove the black and blue wires from limit ther- mostat terminals.

2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.

3.Carefully slide the new limit thermostat into the retaining clip.

4.Refer to FIG. 7 when reconnecting the wires.

BLU from Control

Board

BLK from Terminal

Block

P1800

FIG. 7 LIMIT THERMOSTAT WIRING

Page 26

29707 112801

 

Page 26
Image 26
Bunn CDBCF APS-DV, CDBCF-DV, CDBC APS-DV, CDBC-MV, CDBC-DV, CDBCF APS-MV, CDBCF-MV service manual SERVICE cont LIMIT THERMOSTAT