SERVICE (cont.)
LIMIT THERMOSTAT
P1854 |
FIG. 6 LIMIT THERMOSTAT |
Location:
The limit thermostat is located inside the front access panel on the front side of the tank.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the blue and black wires from the limit thermostat.
3.With an ohmmeter, check for continuity across the limit thermostat terminals.
If continuity is present as described, the limit thermo- stat is operating properly.
If continuity is not present as described, replace the limit thermostat.
Removal and Replacement:
1.Remove the black and blue wires from limit ther- mostat terminals.
2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.
3.Carefully slide the new limit thermostat into the retaining clip.
4.Refer to FIG. 7 when reconnecting the wires.
BLU from Control
Board
BLK from Terminal
Block
P1800
FIG. 7 LIMIT THERMOSTAT WIRING
Page 26 | 29707 112801 |
|