SERVICE (cont.) |
|
REFILL VALVE | If continuity is not present as described, replace the |
| refill valve. |
|
6. Check the refill valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON' upper position press start switch and listen carefully in the vicinity of the refill valve for a" clicking" sound as the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not pass through the refill valve, there may be a blockage in the water line before the refill valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.
If the sound is not heard as described, replace the refill valve.
| P1857 | Removal and Replacement: | |
|
| ||
| FIG. 12 REFILL VALVE | 1. | Remove both wires from the refill valve. |
|
| 2. | Turn off the water supply to the brewer and drain |
Location: |
| the tank. | |
3. | Disconnect the water lines to and from the refill | ||
| The refill valve is located inside the trunk on the |
| valve. |
lower center part of the component bracket. | 4. | Remove the two | |
Test Procedures: |
| valve mounting bracket to the component bracket. | |
| Remove bracket and valve as an assembly. | ||
1. Disconnect the brewer from the power source. | 5. | Using two | |
2. Disconnect the white and white/blue wires from |
| valve and bracket to the component bracket. | |
| the refill valve. Set the "ON/OFF" switch in the "ON" | 6. | Securely fasten the water lines to and from the |
| upper position. |
| valve. |
3. With a voltmeter, check the voltage across the coil | 7. | Refer to FIG. 13 when reconnecting the wires. | |
| wires. Connect the brewer to the power source. | 8. | Install access panels and covers and refer to Initial |
| The indication must be 120 volts ac for two wire |
| |
| 120 volt models and three wire 120/208 and 120/ |
|
|
| 240 volt models. |
|
|
4. Disconnect the brewer from the power source. |
|
| |
If voltage is present as described, proceed to #5. |
|
| |
If voltage is not present as described, refer to Wiring |
|
| |
Diagrams and check brewer wiring harness. |
|
| |
5. | Check for continuity across the refill valve coil | WHI from Terminal | |
| terminals. | Block | |
If continuity is present as described, reconnect the | WHI/BLU from | ||
Control Board | |||
white and white/blue wires from the circuit board. |
| P1858 | |
|
| ||
| Page 30 | FIG. 13 REFILL VALVE WIRING | |
| 29707 112801 | ||
|
|