SERVICE |
|
|
|
|
|
|
|
This section provides procedures for testing and |
|
|
|
|
|
|
|
replacing various major components used in this |
|
|
|
|
|
|
|
brewer should service become necessary. Refer to |
|
|
|
|
|
|
|
Troubleshooting for assistance in determining the |
|
|
|
|
|
|
|
cause of any problem. |
|
|
|
|
|
|
|
WARNING - Inspection, testing, and repair of electri- |
|
|
|
|
|
|
|
cal equipment should be performed only by qualified |
|
|
|
|
|
|
|
service personnel. The brewer should be unplugged |
|
|
|
|
|
| NT R |
|
| TENTS |
|
| IN | R | |
when servicing, except when electrical tests are re- |
| CON | MPLY | RIS | KS |
| |
EL | HOT |
|
|
| |||
FUNNARE | URE | TO CO |
|
|
|
| |
FAIL |
|
|
|
|
| ||
|
|
|
|
|
|
| |
quired and the test procedure specifically states to |
|
|
|
|
|
|
|
plug in the brewer. |
|
|
|
|
|
|
|
COMPONENT ACCESS |
|
|
|
|
|
|
|
WARNING - Disconnect the brewer from the power |
|
|
|
|
|
|
|
source before the removal of any panel or the replace- |
|
|
|
|
|
|
|
ment of any component. |
|
|
|
|
|
|
|
All components are accessible by the removal of |
|
|
|
|
|
|
|
the top cover or warmer housing, front access panel |
|
|
|
|
|
|
|
and warmer plate(s). |
|
|
|
|
|
|
|
The top cover is attached with one |
|
|
|
|
|
| E |
|
|
|
|
|
| A | |
|
|
|
|
| R | D | |
|
|
|
| IS: |
|
| |
|
|
|
|
|
|
| |
The front access panel is attached with four |
|
|
|
|
|
|
|
screws. |
|
|
|
|
|
|
|
Each warmer assembly is attached with three #4- |
|
|
|
|
|
|
|
40 screws. |
|
|
|
|
|
|
|
Contents |
|
|
|
|
|
|
|
Control Board .................................................... 22 |
|
|
|
|
|
|
|
Switch Panel ...................................................... 23 |
|
|
|
|
|
|
|
Dispense Valve .................................................. 24 |
|
|
|
|
|
|
|
Limit Thermostat ............................................... 25 |
|
|
|
|
|
|
|
Tank Heaters ...................................................... 26 |
|
|
|
|
|
|
|
Voltage Selector Switch ..................................... 28 |
|
| ! |
|
|
|
|
|
|
|
|
|
|
| |
Refill Valve ......................................................... 29 |
|
|
|
|
|
|
|
Warmer Elements .............................................. 30 |
|
|
|
|
|
|
|
Fuse Holder and Fuse ........................................ 31 |
|
|
|
|
|
|
|
Thermal Fuse ..................................................... 32 |
|
|
|
|
|
|
|
Wiring Diagrams ............................................... 33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| P1889 |
| FIG. 1 COMPONENT ACCESS | ||||||
Page 22 |
|
|
|
|
|
| 29707 112801 |
|
|
|
|
|
|
|