TROUBLESHOOTING (cont.) |
| |
HEATING CIRCUIT (cont.) |
| |
PROBLEM |
| PROBABLE CAUSE |
Water does not heat to proper tem- | 6. Tank Heater | |
perature (cont.) |
| |
IMPORTANT: Make sure no tem- |
| |
perature tests are taken before the |
| |
ready light is "ON". Tank tempera- |
| |
ture must be stabilized before read- |
| |
ings are taken. |
|
REMEDY
Disconnect the brewer from the power source. Check for continuity between the white terminal of the terminal block (or red terminal on 208/240volt models) and the black wire on the relay on the control board (Toggle Switch must be in
7.Fuse Holder & Fuse (MV models only)
8.Thermal Fuse (MV models only)
Check fuse and replace if neces- sary. (See page 31)
Check thermal fuse for continuity and replace if necessary. (See page 32)
Page 15 | 29707 112801 |
|