Bunn CDBC APS-DV, CDBCF-DV, CDBC-MV, CDBC-DV, CDBCF APS-MV, CDBCF APS-DV TROUBLESHOOTING cont

Models: CDBCF-MV CDBCF APS-DV CDBCF APS-MV CDBC-DV CDBC-MV CDBC APS-DV CDBCF-DV

1 37
Download 37 pages 654 b
Page 15
Image 15
Manual background

TROUBLESHOOTING (cont.)

 

HEATING CIRCUIT (cont.)

 

PROBLEM

 

PROBABLE CAUSE

Water does not heat to proper tem-

6. Tank Heater

perature (cont.)

 

IMPORTANT: Make sure no tem-

 

perature tests are taken before the

 

ready light is "ON". Tank tempera-

 

ture must be stabilized before read-

 

ings are taken.

 

REMEDY

Disconnect the brewer from the power source. Check for continuity between the white terminal of the terminal block (or red terminal on 208/240volt models) and the black wire on the relay on the control board (Toggle Switch must be in 120/208-240V position on 208V & 240V models). There should be a low OHM reading. If no continuity is present, check for a wiring prob- lem, then replace the tank heater if no wiring problem is found. (See page 26)

7.Fuse Holder & Fuse (MV models only)

8.Thermal Fuse (MV models only)

Check fuse and replace if neces- sary. (See page 31)

Check thermal fuse for continuity and replace if necessary. (See page 32)

Page 15

29707 112801

 

Page 15
Image 15
Bunn CDBC APS-DV, CDBCF-DV, CDBC-MV, CDBC-DV, CDBCF APS-MV, CDBCF APS-DV, CDBCF-MV service manual TROUBLESHOOTING cont