DIGITAL BREW TIMER (Late Models)
P1127.40 |
FIG. 18 DIGITAL BREW TIMER |
Location:
The timer is located inside the front of the trunk on the top of the component bracket.
Test Procedure.
NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.
1.Disconnect the brewer from the power source and remove the front access panel.
2.Remove the two
3.Remove circuit board and spacers (as required).
4.With a voltmeter, check the voltage across termi- nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be:
a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.
b)200 to 240 volts ac on two wire 200 volt or 240 volt models.
c)100 volts ac for two wire 100 volt models.
5.Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.
6.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.
If voltage is as described, proceed to #7.
If voltage is not as described, disconnect the brewer from the power source and replace the timer.
7.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica- tion must be as follows:
a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.
b)200 to 240 volts ac on two wire 200 volt or 240 volt models.
c)100 volts ac for two wire 100 volt models.
If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume.
If voltage is not present as described, disconnect the brewer from the power source and replace the timer.
Removal and Replacement:
1.Remove the two
2.Remove circuit board and spacers (as required).
3.Remove all wires from the timer.
4.Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 19 when reconnecting the wires.
5.Install new circuit board with spacers (as re- quired) to the component mounting bracket.
6.Adjust the timer as described below.
Page 27 | 10690 062300 |
|