TROUBLESHOOTING (cont.) | 
  | 
  | 
  | 
  | 
PROBLEM | PROBABLE CAUSE | 
  | REMEDY | |
Brew cycle will not start (cont.)  | 3. ON/OFF Switch  | 
  | Refer to Service - ON/OFF Switch  | |
  | 
  | 
  | for testing. See page 18  | |
 | 4. Start Switch  | 
  | Refer to Service - Start Switch for  | |
TSR) | 
  | |||
  | 
  | 
  | 
  | testing procedures. See page 20  | 
  | 5. Timer  | 
  | 
  | Refer to Service - Timer for testing  | 
  | 
  | 
  | 
  | procedures. See page 25 or 27  | 
  | 6. Solenoid Valve  | 
  | Refer to Service - Solenoid Valve  | |
  | 
  | 
  | 
  | for testing procedures. See page  | 
  | 
  | 
  | 
  | 19  | 
  | 7. Water  | strainer/flow  | control  | (A) Direction of flow arrow must  | 
  | (.222 GPM)  | 
  | be pointing towards brewer.  | |
  | 
  | 
  | 
  | (B) Remove the strainer/flow con-  | 
  | 
  | 
  | 
  | trol and check for obstructions.  | 
  | 
  | 
  | 
  | Clear or replace.  | 
Water is not hot  | 1. Tank Heater Switch  | 
  | Refer to Service - Tank Heater  | |
  | 
  | 
  | 
  | Switch for testing procedures. See  | 
  | 
  | 
  | 
  | page 23  | 
  | 2. Limit Thermostat  | 
  | Refer to Service - Limit Thermo-  | |
  | CAUTION - Do not eliminate or  | stat for testing procedures. See  | ||
  | bypass limit thermostat. Use only  | page 17  | ||
  | BOM | replacement  | part  | 
  | 
  | #29329.1000  | 
  | 
  | |
  | 3. Control Thermostat  | 
  | Refer to Service - Control Ther-  | |
  | 
  | 
  | 
  | mostat for testing procedures. See  | 
  | 
  | 
  | 
  | page 16  | 
  | 4. Tank Heater  | 
  | Refer to Service - Tank Heater for  | |
  | 
  | 
  | 
  | testing procedures. See page 21  | 
Page 10  | 10690 062300  | 
  |