SERVICE | 
  | 
This section provides procedures for testing and  | 
  | 
replacing various major components used in this  | 
  | 
brewer should service become necessary. Refer to  | 
  | 
Troubleshooting for assistance in determining the  | 
  | 
cause of any problem.  | 
  | 
WARNING - Inspection, testing, and repair of electri-  | 
  | 
cal equipment should be performed only by qualified  | 
  | 
service personnel. The brewer should be unplugged  | 
  | 
when servicing, except when electrical tests are re-  | 
  | 
quired and the test procedure specifically states to  | 
  | 
  | |
COMPONENT ACCESS | 
  | 
WARNING - Disconnect the brewer from the power  | |
source before the removal of any panel or the replace-  | |
ment of any component.  | 
  | 
All components are accessible by the removal of  | 
  | 
the top cover and front inspection panel.  | 
  | 
The top cover is attached with one   | 
  | 
The front inspection panel is attached with six #6-  | 
  | 
32 screws on APS and TS Models and eight   | 
  | 
screws on and TSR Models  | 
  | 
Contents | |
  | |
Control Thermostat ............................................. 16  | 
  | 
Limit Thermostat ................................................ 17  | 
  | 
ON/OFF Switch .................................................... 18  | 
  | 
Solenoid (Inlet) ................................................... 19  | 
  | 
Start Switch (Brew) ............................................ 20  | 
  | 
Tank Heater ........................................................ 21  | 
  | 
Tank Heater Switch ............................................. 23  | 
  | 
Timer (Early Models) .......................................... 25  | 
  | 
Digital Timer (Late Models) ................................ 27  | 
  | 
Wiring Diagrams .................................... 29 thru 33  | 
  | 
  | |
  | P1126.30  | 
  | FIG. 1 COMPONENT ACESS | 
Page 15  | 10690 062300  | 
  |