TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming (cont.)
Dripping from sprayhead
Water flows into tank continuously (ON/OFF Switch "ON")
Water flows into tank continuously (ON/OFF Switch "OFF")
Beverage overflows dispenser
PROBABLE CAUSE
2. Control Thermostat
1.Syphon System
2.Lime Build-up
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
3.Solenoid Valve
1.Timer
1.Solenoid Valve
1.Dispenser
2.Timer
3.Solenoid Valve
REMEDY
Refer to Service - Control Ther- mostat for testing procedures. See page 16
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary.
See page 19
Refer to Service - Timer for testing procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 19
The dispenser must be completely empty before starting a brew cycle.
Refer to Service - Timer for testing procedures. See page 25 or 27
Remove the Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 19