SERVICE (cont.)
SOLENOID VALVE | If continuity is not present as described, replace the |
solenoid valve. |
P1127.40 |
FIG. 8 SOLENOID VALVE |
Location:
The solenoid valve is located inside the trunk on the center lower part of the component bracket.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the white and black wires from the solenoid valve. With the "ON/OFF" switch in the "ON" (upper) position press the start switch.
3.With a voltmeter, check the voltage across the white and black wires. Connect the brewer to the power source. The indication must be:
a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.
b)200 to 240 volts ac for two wire 200 or 240 volt models.
c)100 volts ac for two wire 100 volt models.
4.Disconnect the brewer from the power source,
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to Wiring Diagrams and check brewer wiring harness.
5.Check for continuity across the solenoid valve coil terminals.
If continuity is present as described, reconnect the white and black wire from the timer.
6.Check the solenoid valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON" (upper) position press start switch and listen carefully in the vicinity of the solenoid valve for a" clicking" sound as the coil magnet attracts.
7.Disconnect the brewer from the power source.
If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before the solenoid valve, or the solenoid valve may require inspection for wear and removal of waterborne particles.
If the sound is not heard as described, replace the solenoid valve.
Removal and Replacement:
1.Remove the white and black wires from the sole- noid valve.
2.Turn off the water supply to the brewer.
3.Disconnect the water lines to and from the sole- noid valve.
4.Remove the two
5.Remove the two
6.Using two
7.Using two
8.Securely fasten the water lines to and from the solenoid valve.
9.Refer to Fig. 9 when reconnecting the wires.
WHI from Timer
BLK from Timer
P1132.50
FIG. 9 SOLENOID VALVE TERMINALS
Page 19 | 10690 062300 |
|