TROUBLESHOOTING (cont.)
BREWING CIRCUIT
| PROBLEM | 
 | PROBABLE CAUSE | 
 | REMEDY | |
| Brew cycle will not start | 
 | 1. Display's error message | Brewer has shut down due to mal- | ||
| 
 | 
 | 
 | 
 | 
 | function. See Diagnostics. | 
| 
 | 2. | No water | Water lines and valves to the brewer | ||
| 
 | 
 | 
 | 
 | 
 | must be open. | 
| 
 | 
 | 3. No power or incorrect voltage to | Check for voltage across the termi- | ||
| 
 | 
 | the brewer | nals at the terminal block. | ||
| 
 | 4. | ON/OFF switch not in the "ON" | The indicator lamp must be lit | ||
| 
 | 
 | position | 
 | ||
| 
 | 5. | Low water temperature (Brew | Allow brewer to heat until ready, or | ||
| 
 | 
 | lockout is enabled) | disable the brew lockout feature. | ||
| 
 | 
 | 
 | 
 | 
 | Water must be in contact with refill | 
| 
 | 6. | Water not touching refill probe | probe before brew cycle will start. | ||
| 
 | 
 | inside tank | 
 | ||
| 
 | 7. | Membrane Switch | Check/replace | ||
| 
 | 8. | Dispense valve | Check/replace | ||
| 
 | 9. | Control board | Check/replace | ||
| 
 | 
 | ||||
| Consistently low beverage level in | 
 | 1. Brew volume | Inspect the dispense valve and | ||
| the dispenser or beverage overflows | 
 | NOTE: Volume adjustments must be | sprayhead for excessive lime de- | ||
| dispenser | 
 | made with sprayhead installed. | posits. Delime as required. | ||
| 
 | 2. | Lime build up | Remove dispense valve and clear | ||
| 
 | 
 | 
 | 
 | 
 | any obstructions. Rebuild or replace | 
| 
 | 
 | 
 | 
 | 
 | valve if necessary. (See page 24) | 
| 
 | 3. | Dispense Valve | Check/replace | ||
| 7 | 42461 0911809 | 
| 
 | 