Bunn ITB/ITCB, ICB/TWIN TROUBLESHOOTING cont BREWING CIRCUIT, Problem, Probable Cause, Remedy

Models: ITB/ITCB ICB/TWIN

1 30
Download 30 pages 63.74 Kb
Page 7
Image 7

TROUBLESHOOTING (cont.)

BREWING CIRCUIT

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Brew cycle will not start

 

1. Display's error message

Brewer has shut down due to mal-

 

 

 

 

 

function. See Diagnostics.

 

2.

No water

Water lines and valves to the brewer

 

 

 

 

 

must be open.

 

 

3. No power or incorrect voltage to

Check for voltage across the termi-

 

 

the brewer

nals at the terminal block.

 

4.

ON/OFF switch not in the "ON"

The indicator lamp must be lit

 

 

position

 

 

5.

Low water temperature (Brew

Allow brewer to heat until ready, or

 

 

lockout is enabled)

disable the brew lockout feature.

 

 

 

 

 

Water must be in contact with refill

 

6.

Water not touching refill probe

probe before brew cycle will start.

 

 

inside tank

 

 

7.

Membrane Switch

Check/replace

 

8.

Dispense valve

Check/replace

 

9.

Control board

Check/replace

 

 

Consistently low beverage level in

 

1. Brew volume

Inspect the dispense valve and

the dispenser or beverage overflows

 

NOTE: Volume adjustments must be

sprayhead for excessive lime de-

dispenser

 

made with sprayhead installed.

posits. Delime as required.

 

2.

Lime build up

Remove dispense valve and clear

 

 

 

 

 

any obstructions. Rebuild or replace

 

 

 

 

 

valve if necessary. (See page 24)

 

3.

Dispense Valve

Check/replace