TROUBLESHOOTING (cont.)

HEATING CIRCUIT

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Water does not heat to proper

1.

Display's error message

 

Brewer has shut down due to mal-

temperature

 

 

 

function. See Diagnostics.

IMPORTANT: Make sure no tem-

 

 

 

 

perature tests are taken before

2. Water not touching main (short)

 

Remove level probe and grommet.

the display reads ready. Tank tem-

level probe

 

Look into hole on tank lid. Water

perature must be stabilized before

 

 

 

must be within approximately one

readings are taken.

 

 

 

inch from top of tank.

 

 

3. Water Level Probe Sensing

 

Check refill circuit. Heaters will not

 

 

System

 

turn on if water is not grounding

 

 

 

 

 

level probe.

 

 

4.

Temperature Probe

 

Check/replace

 

 

5.

Limit Thermostat or TCO

 

Check/replace

 

 

6.

Tank Heater

 

Check/replace

Spitting or excessive steaming

1.

Lime build up on temperature

 

Inspect probe and tank assembly

(cont.)

probe, tank or tank heater

 

for excessive lime deposits. Delime

 

 

 

 

 

as required.

 

 

2.

Temperature Probe

 

Check/replace

 

 

3.

Control Board

 

Check/replace

Brewer is making unusual noises

1.

Plumbing lines

 

Plumbing lines should not rest on

 

 

 

 

 

the counter top.

 

 

2.

Water supply

 

The brewer must be connected to

 

 

 

 

 

a cold water supply.

 

 

3.

Lime build up

 

Remove the tank lid and clean in-

 

 

 

 

 

side of tank with a deliming agent,

 

 

 

 

 

if necessary.

6

42461 0911809

 

Page 6
Image 6
Bunn ICB/TWIN, ITB/ITCB manual Heating Circuit Problem Probable Cause Remedy