PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

REFILLRange: 0 to 155

This function allows the operator to adjust the sensitivity of the refill circuit. This is mainly a troubleshooting feature. Water in different geographical locations can have different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to operate under various water conditions.

Procedure to set the sensitivity threshold of the refill circuit:NOTE: Make sure the water in the tank is touching the refill probe.

1.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads REFILL and shows a number on both sides of the word.

2.To adjust the threshold setting, press (-)to decrease or (+) to increase the setting.

NOTE: Always make sure that the number on the right is larger than the number on the left when water is in contact with the refill probe in the tank.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen SPRAY OZ/M. To exit programming and return to the MAIN SCREEN, press and release the ON/OFF pad.

XXXREFILL 155 (-) DONE (+)

BREW

BREW

BREW

A

B

C

SPRAY OZ/M: XX.X (-) DONE (+)

BREW

BREW

BREW

A

B

C

P2876