PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

DILUTE OZ/M

This function allows the operator to view or to enter the actual flow rate coming out of the dilution nozzle. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing.

Procedure to adjust the dilution flow rate setting:

1.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hid- den button until the display reads DILUTE OZ/M. The number represents what the brewer thinks is the flow rate out of the dilution nozzle.

2.If the actual flow rate of the nozzle is known but is different than the number on the display, use the (-)and (+) to enter the correct flow rate.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen, CALIBRATE FLOW. To exit programming and return to the MAIN SCREEN, press and release the ON/OFF pad.

DILUTE OZ/M: XX.X

(-) DONE (+)

BREW

BREW

BREW

A

B

C

CALIBRATE FLOW?

NO YES

BREW

BREW

BREW

A

B

C

P2878