PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

CALIBRATE FLOW (Continued)Procedure to calibrate the dilution flow rate:

1.Place a container, accurately graduated and with a minimum capacity of 130 ounces, beneath the funnel.

NOTE: If the display is already on the DILUTION CAL screen, skip steps 2 & 3 and proceed directly to step 4.

2.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads CALIBRATE FLOW.

3.Press and release YES to advance to the SPRAY HEAD CAL function screen. Press and release NO to advance to DILUTION CAL.

4.Press and release the YES pad. The display should read CONTAINER READY? If the container is under the funnel, press YES.

5.The display should read CALIBRATE DILUTE. Press and release START to begin the dilution flow for calibration. The display should read CALIBRATE DILUTE...60 SEC TO FINISH. The 60-second timer on the display will count down to zero. When the counter reaches zero, the display will changes to DILUTE OZ/M, along with a number.

6.Measure the amount of water in the container and using the (-)and (+) pads, adjust the amount of the display to match the amount in the container. Then press DONE.

7.The display should now read NEW DILUTE FLOW, along with the correct flow rate of the sprayhead. After about 5 seconds, the display will return to the CALIBRATE FLOW screen, BREW COUNTERS. To exit programming, press and release the ON/OFF button to return to the MAIN SCREEN.

CALIBRATE FLOW?

NO YES

PRESSING NO WILL

BREW

BREW

BREW

ADVANCE TO

BREW COUNTERS

A

B

C

 

 

 

 

 

 

 

 

 

 

SPRAY HEAD CAL

NO YES

BREW

BREW

BREW

A

B

C

DILUTION CAL?

NO YES

BREW

BREW

BREW

A

B

C

CONTAINER READY?QUIT YES

BREW

BREW

BREW

A

B

C

CALIBRATE DILUTEQUIT START

BREW

BREW

BREW

A

B

C

CALIBRATE DILUTE 60 SEC TO FINISHDILUTE OZ XX.X

(-) DONE (+)

BREW

BREW

BREW

A

B

C

NEW DILUTE FLOWXX.X OZ/M

5 SEC.

CALIBRATE FLOW?

NO YES