PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

SPRAY OZ/M

This function allows the operator to view or to enter the actual flow rate coming out of the sprayhead. This is NOT used to change the actual flow rate, but to tell the internal controller how fast the water is flowing.

Procedure to adjust the sprayhead flow rate set- ting:

1.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hid- den button until the display reads SPRAY OZ/M . The number represents what the brewer thinks is the flow rate out of the sprayhead.

2.If the actual flow rate of the sprayhead is known but is different than the number on the display, use the (-)and (+) to enter the correct flow rate.

3.When finished, press and release DONE. This saves the new setting and advances to the next function screen, DILUTE OZ/M. To exit programming and return to the MAIN SCREEN, press and release the ON/OFF pad.

SPRAY OZ/M: XX.X (-) DONE (+)

BREW

BREW

BREW

A

B

C

DILUTE OZ/M: XX.X

(-) DONE (+)

BREW

BREW

BREW

A

B

C

P2877

Page 48

36748 041504