TROUBLESHOOTING (cont.)

 

 

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Automatic refill will not operate or5. Refill valve (Continued)

 

secure. Test the refill valve. Refer

display shows FILL TIME TOO LONG

 

 

to the test outputs procedures on
(Continued)

 

 

page 56.

 

 

 

 

Refill valve – Disconnect the brewer

 

 

 

 

from the power source and remove

 

 

 

 

wires from refill valve coil. Check

 

 

 

 

for continuity across the terminals

 

 

 

 

of the solenoid coil. If continuity is

 

 

 

 

not present, replace the refill valve.

 

 

 

 

If continuity is present, the coil may

 

 

 

 

be stuck closed. Shut water off to

 

 

 

 

brewer. Press the ON/OFF switch to

 

 

 

 

turn off the brewer. Open the faucet

 

 

 

 

and drain water down in the tank

 

 

 

 

until flow stops or slows to a trickle.

 

 

 

 

Attach a voltmeter to the terminals

 

 

 

 

of the refill solenoid. Connect the

 

 

 

 

brewer to the power source. Press

 

 

 

 

the ON/OFF switch to turn the brewer

 

 

 

 

on. Within five seconds, voltage

 

 

 

 

should be present at the solenoid

 

 

 

 

terminals. If voltage is not present,

 

 

6. Control Board

 

refer to the wiring schematic and

 

 

 

 

check the wiring harness.

 

 

7. ON/OFF Switch

 

Substitute a control board known

 

 

 

 

to be in good working order.

Page 67