Bunn JDF-4D, JDF-4SB manual SERVICE CONT EMI Filter all Models, Emi Filter, JDF-4S shown

Models: JDF-4D JDF-4SB JDF-4S

1 57
Download 57 pages 43.05 Kb
Page 38
Image 38
SERVICE (CONT.)

SERVICE (CONT.)

EMI Filter (all Models)

JDF-4S shown

FIG. 49 EMI FILTER

Location:

The EMI Filter is located on the electrical component mounting bracket on the lower front of the dispenser behind the splash panel.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the two black wires and two white wires on the EMI Filter from the power cord and the main wiring harness.

3.Check for resistance between the two black leads on the EMI Filter.

If resistance is present as described the EMI Filter is operating properly.

If resistance is not present as described, replace the EMI Filter.

Removal and Replacement:

1.Disconnect the wires from the EMI Filter.

2.Remove the two #8-32 screws and nuts securing the EMI Filter.

3.Remove and discard EMI Filter.

4.Install new EMI Filter using two #8-32 screws and nuts to secure EMI Filter to its former location.

5.Refer to Fig. 50 when reconnecting the wires.

118.0 kΩ - 118.5 kΩ

Across either pair

FIG. 50 EMI FILTER CONNECTORS