Bunn JDF-4SB, JDF-4D manual SERVICE CONT Condenser Fan all Models, Location, Blu/Blk

Models: JDF-4D JDF-4SB JDF-4S

1 57
Download 57 pages 43.05 Kb
Page 24
Image 24
SERVICE (CONT.)

SERVICE (CONT.)

Condenser Fan (all Models)

JDF-4S shown

P1684.40

FIG. 21 CONDENSER FAN

Location:

The condenser fan is located inside the main frame below the compressor assembly.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the 2-pin from the fan to the main wiring harness.

3.Check for continuity across the fan terminals.

If continuity is present as described, reconnect the wires to the fan terminals.

If continuity is not present as described, replace the fan.

Removal and Replacement:

1.Disconnect the dispenser from the power source.

2.Remove the four screws attaching the fan and cover assembly to the refrigeration cabinet.

3.Gently pull the cover assembly forward and discon- nect the 2-pin connector from the fan to the main harness.

4.Remove the fan from the cover assembly and dis- card.

5.Install the new fan onto the cover assembly.

6.Reconnect the wiring harness to the new fan.

7.Install fan and cover assembly using four screws previously removed.

8.Reconnect power to the dispenser.

BLU/BLK

WHI P1219

FIG. 22 CONDENSER FAN TERMINALS

24

49179

110613

 

Page 24
Image 24
Bunn JDF-4SB, JDF-4D manual SERVICE CONT Condenser Fan all Models, Location, Blu/Blk