Bunn JDF-4SB, JDF-4D SERVICE CONT Transformer all Models, WHI/BLU to Control, Board J6-1,J12-1

Models: JDF-4D JDF-4SB JDF-4S

1 57
Download 57 pages 43.05 Kb
Page 48
Image 48
SERVICE (CONT.)
FIG. 69 TRANSFORMER

SERVICE (CONT.)

Transformer (all Models)

 

AC

A C

+

P3864

Location:

The transformer is located on the electrical com- ponent mounting bracket on the lower front of the dispenser behind the splash panel.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Check the voltage across black wire and the white wire from the main harness. Connect the dispenser to power source. The indication must be:

a)120 volts ac for two wire 120 volt models, three wire 120/208 volt and three wire 120/240 volt models.

b)240 volts ac for two wire 240 volt models.

c)230 volts ac for two wire 230 volt models.

4. Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the Wiring Diagrams and check the main wiring harness.

5.Check the voltage between J6-1 and J6-3 at the control board. Connect the dispenser to the power source. The indication must be 24 volts ac.

If voltage is present as described the transformer is operating properly.

If voltage is not present as described, replace the transformer.

Removal and Replacement:

1.Loosen the two #8-32 screws securing the com- ponent bracket to the dispenser housing base.

2.Pull component bracket out the front of the dispenser far enough so the transformer can be disconnected from the main wiring harness.

3Remove the two #6-32 keps nuts securing the transformer to the component bracket.

5.Remove and discard the transformer.

6.Install new transformer on the component bracket and secure with two #6-32 keps nuts.

7.Refer to Fig. 70 and connect the transformer to the main wiring harness.

8.Place the component bracket into position and tighten the two #8-32 screws.

 

WHI from

WHI/BLU to Control

Power Cord

Board J6-1,J12-1

BLK from

 

Power Cord

BLU

to Control

Board J6-3,J12-3

 

P1647

FIG. 70 TRANSFORMER TERMINALS

48

49179

110613

 

Page 48
Image 48
Bunn JDF-4SB, JDF-4D manual SERVICE CONT Transformer all Models, WHI/BLU to Control, Board J6-1,J12-1, Board J6-3,J12-3