SERVICE (CONT.)

SERVICE (CONT.)

LED Lamps (JDF-2S, JDF-4S)

LED regulator board

FIG. 53 LED DOOR LIGHTS

Location:

The LED door lights are located inside the dispenser door.

Test Procedures:

No illumination at all: First verify that the dispense lockout switch has not been turned off!

1.Disconnect power from the dispenser.

2.Check the voltage across the black and red leads ofJ2 or J3 at the LED regulator board with a voltmeter. Reconnect power to the dispenser. The indication must be 24 volts dc.

3.Disconnect power from the dispenser.

If voltage is present as described, the LED regulator board is working correctly.

If voltage is not present as described, go to step 4.

4.Check for supply voltage (unregulated +30VDC) across brown wire and white wire at J1 of the regulator board. (FIG 54).

If voltge is present as described, replace LED regulator board.

If voltage is not present as described, check the wiring back to the main CBA.

Removal and Replacement:

1.Disconnect power from the dispenser.

2.Remove the five #6-32 screws securing the door cover to the door.

3.Carefully lower the door cover and disconnect the lamp terminals from the LED regulator board.

4.Remove and discard the faulty LED board.

5.Install a new LED regulator board exposing the adhesive backing.

6.Refer to Fig. 54 and reconnect wires to the LED regulator board.

7.Replace the door cover and secure with the five #6-32 screws.

8.Return power to the dispenser.

J3

J2

J1

White to brown

unregulated +30VDC

FIG. 54 LED DOOR LIGHT WIRING

40