Bunn JDF-4D TROUBLESHOOTING Continued, Problem, Probable Cause, Step-down transformer, Remedy

Models: JDF-4D JDF-4SB JDF-4S

1 57
Download 57 pages 43.05 Kb
Page 11
Image 11

TROUBLESHOOTING (Continued)

PROBLEM

PROBABLE CAUSE

REMEDY

Unit is not working

1. Step-down transformer.

Check for 120/24 or 230/24 vac. If no 24vac reading, replace step-down transformer.

 

2. Main control board.

If 24 vac present and no LED’s lit,

 

 

replace control board..

Difficulty brixing and/or weak bever-

1. Product viscosity or too cold.

Thorough thaw of product before use

age

 

(35° - 40°)

 

2. Low water pressure.

Maintain 20 psi or higher and a mini-

 

 

mum flow rate of 1 fl oz/sec.

 

3. High water pressure.

Over 100 psi, install a pressure regu-

 

 

lator and set to 50 psi.

 

4. Dispense valve adjustment set-

A) Perform 3 second water dispense

 

ting.

test. Factory setting is 1.0 oz/sec.

 

 

Acceptable water flow rate is .-0.8

 

 

to 1.5 oz/sec depending on the mix

 

 

ratio (4+1).

 

 

B) Adjust water to proper mix ratio.

 

 

Once water is set, adjust motor speed

 

 

to achieve brix %.

 

5. Brix ratio.

Check for proper brix ratio per prod-

 

 

uct using Total Dispense method and

 

 

or refractometer method.

Difficulty brixing and/or weak bever-

1. Pump tubing.

Inspect, clean, or replace tubing

age

 

and pump rotor/rollers for ease of

 

 

rotation.

 

2. Use of portable water pump.

A) Follow plumbing requirements for

 

 

pressure and flow rate.

 

 

B) Source another portable pump

 

 

or water supply that meets require-

 

 

ments.

Difficulty brixing bag-in-box

Vacuum leak

Inspect all lines and connections

 

 

from bag-in-box connector to bottle

 

 

adapter assembly.

11

49179

110613

 

Page 11
Image 11
Bunn JDF-4D TROUBLESHOOTING Continued, Problem, Probable Cause, Step-down transformer, to 1.5 oz/sec depending on the mix