TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel.

All electronic components have high voltage ac and low voltage dc potential on their terminals. Shorting of terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

This unit is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

Unplug the dispenser when servicing, except when electrical tests are specified.

Follow recommended service procedures

Replace all protective shields or safety notices

PROBLEM

PROBABLE CAUSE

Cold Water Circulation

1.

Cabinet cooling fan.

Dispense stations not working.

 

 

Note: Cooling failure or excessive

 

 

cabinet temperatures for more than 4

2.

Bath recirculation pump.

hours will result in dispense lockout

or no dispense.

 

 

Note: Reset fault/timer by unplug-

 

 

ging unit.

 

 

REMEDY

Replace fan (24vdc).

Note: Fan receives power when the dispenser is powered.

A)If not running, check refrigeration switch and wiring for proper conti- nuity.

B)Check for 120V or 230V AC at pump. Replace pump.

3. Restricted water flow to cabinet Check for kinked hose. water coil and bath.