PROGRAMMING THE BREWER (cont.)

ENABLE ENERGYSAVR

This function allows the operator to enable the ENERGY SAVINGS mode function and set the idle time. Once the set idle time has expired, the operator can choose to have the heaters either turn off, or reduce the tank holding temp to 140° F (60° C).

Procedure to enable energy savings mode: Range: 0.5 to 24.0 hrs

If enabled, default setting is 140° F (60° C) tank tem- perature after 4.0 hrs. idle time.

1.

Press and hold the right hidden switch until the

 

display reads SET LANGUAGE. Press the right

 

hidden switch until the display reads Enabl Ener-

 

gySavr. The YES or NO will be flashing to indicate

 

the current selection.

2.

Press and release NO to disable this function, or:

3.

Press and release YES to enable this function (the

 

heaters will either turn off or the tank will hold at

10.Once the idle time has expired, the display will read either ENERGY SAVER...NO TEMPERATURE or ENERGY SAVER...REDUCED TEMPERATURE, depending on the settings. This screen will alternate with PRESS ANY SWITCH TO RE-HEAT.

Enabl EnrgySavr

NO DONE YES

WITH YES FLASHING

PRESS DONE

 

140° F).

4.

When finished, press and release DONE to save

 

the new setting and advance to the next function

 

screen.

5.

If NO was selected, the display should now read

 

SET NEW RECIPE ?. To exit programming and

 

return to the MAIN SCREEN, press and release

 

the ON/OFF switch (either for DUAL Brewers).

6.

If YES was selected, the display should now read

 

X.X HRS -> IDLE. This screen allows the opera-

WITH NO FLASHING

PRESS DONE TO

ADVANCE TO

ENABLEFRESHTIMER

X.X HRS -> IDLE (-) DONE (+)

AFTER IDLE TIME? OFF DONE 140°

tor to set the amount of time the brewer is not in

use before nap mode engages. Using (-)and (+),

adjust the idle time. When finished, press and

release DONE.

7. The display should now read AFTER IDLE TIME?

Once the set idle time has expired, the heaters can

either be shut off or held at a lower temperature

of 140° F.

8. To have the machine shut off after the set idle time,

press and release OFF and then DONE to save the

settings. The display should read MACHINE OFF

AFTER X.X HRS, and then SET NEW RECIPE ?.

9. To have the heaters hold at the lower 140° F tem-

perature, press and release 140° and then DONE

to save the settings. The display should read

MACHINE AT 140° AFTER X.X HRS, and then SET

NEW RECIPE ?.

MACHINE OFF

MACHINE AT 140°

AFTER X.X HRS

AFTER X.X HRS

SET NEW RECIPE ?

NO DONE YES

Page 12

41341 101911

 

Page 12
Image 12
Bunn SNG0033000 manual Enable Energysavr, NEW Recipe ?