TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | |
Brew cycle will not start (cont.) | 4. | ON/OFF Switch |
| 5. | Start Switch |
| 6. | Brew Timer |
REMEDY
Refer to Service - ON/OFF Switch for testing. See page 24
Refer to Service - Start Switch for testing procedures. See page 26
Refer to Service - Brew Timer for testing procedures. See page 17 or 18
7. Brew Solenoid Valve | Refer to Service - Brew Solenoid |
| Valve for testing procedures. See |
| page 16 |
8. Internal Flow control (.195 GPM)
Water is not hot | 1. Limit Thermostat |
| CAUTION - Do not eliminate or by- |
| pass limit thermostat or thermal |
| |
| part 29329.1000 |
(A)Direction of flow arrow must be pointing towards brewer.
(B)Remove the flow control and check for obstructions. Clear or re- place.
Refer to Service - Limit Thermostat for testing procedures. See page 23
| 2. | Control Thermostat |
| 3. | Tank Heater |
Dilution cycle will not start | 1. ON/OFF Switch | |
| 2. | Start Switch |
| 3. | Dilution Timer |
Refer to Service - Control Thermo- stat for testing procedures. See page 20
Refer to Service - Tank Heater for testing procedures. See page 28
Refer to Service - ON/OFF Switch for testing procedures. See page 24
Refer to Service - Start Switch for testing procedures. See page 26
Refer to Service - Dilution Timer for testing procedures. See page 22