Bunn TU3 service manual SERVICE cont, Control Thermostat

Models: TU3

1 32
Download 32 pages 6.71 Kb
Page 20
Image 20
CONTROL THERMOSTAT

SERVICE (cont.)

 

mostat is turned fully clockwise. Connect the

CONTROL THERMOSTAT

 

brewer to the power source. The indication must

 

be:

 

 

 

 

a) 120 volts ac for two wire 120 volt models.

 

 

b) 240 volts ac for two wire 240 volt models.

 

 

c) 100 volts ac for two wire 100 volt models.

 

8.

Disconnect the brewer from the power source.

 

If voltage is present as described, reinstall the capil-

 

lary tube into the tank to the line 4.5" above the bulb,

 

the control thermostat is operating properly.

 

If voltage is not present as described, replace the ther-

 

mostat.

 

Removal and Replacement:

P1276.40

1.

Remove both wires from the control thermostat

FIG. 8 CONTROL THERMOSTAT

 

terminals.

 

 

Location:

2.

Remove the thermostat capillary bulb by firmly

The control thermostat is located inside hood on

 

pulling up on the capillary tube at the tank lid. This

the right side just behind the dilution timer.

3.

will disengage the grommet from the tank lid.

 

Remove the #8-32 screw holding the control ther-

Test Procedures:

 

mostat to its bracket.

1. Disconnect the brewer from the power source.

4.

Slide the grommet to the line 4.5" above the bulb

2. Locate the blue/black wire on the control thermo-

 

on the new capillary tube.

stat.

5.

Insert the capillary bulb through the hole in the

3. With a voltmeter, check the voltage across the blue/

 

tank lid and press the grommet firmly and evenly

black wire on the control thermostat and the white

 

so that the groove in the grommet fits into the

wire on the tank heater for 100 volt and 120 volt

 

tank lid.

two wire models or red wire on the tank heater for

6.

Carefully bend the capillary tube so that the tube

240 volt two wire models. Connect the brewer to

 

and bulb inside the tank are in a vertical position.

the power source. The indication must be:

NOTE Ð The capillary tube must be clear of any elec-

a) 120 volts ac for two wire 120 volt models.

trical termination and not kinked.

b) 240 volts ac for two wire 240 volt models.

7.

Fasten the new control thermostat to its bracket.

c) 100 volts ac for two wire 100 volt models.

8.

Refer to Fig. 9 when reconnecting the wires.

4. Disconnect the brewer from the power source.

9.

Adjust the control thermostat as required.

 

If voltage is present as described, proceed to #5.

 

If voltage is not present as described, refer to the

 

Wiring Diagrams and check the brewer wiring har-

BLK to Tank

ness.

Heater

5. Locate the black wire on the control thermostat.

6.Gently remove the capillary bulb and grommet from the tank.

7. With a voltmeter, check the voltage across the

 

 

BLU/BLK to Limit

 

 

 

 

 

 

black wire of the control thermostat and the white

 

 

Thermostat

 

 

 

 

 

 

 

wire on the tank heater for 100 volt and 120 volt

 

 

 

 

 

two wire models or red wire on the tank heater for

 

 

 

P1280

240 volt two wire models when the control ther-

 

 

 

 

 

FIG. 9 CONTROL THERMOSTAT TERMINALS

 

 

 

Page 20

10225

021599

 

 

 

 

 

Page 20
Image 20
Bunn TU3 service manual SERVICE cont, Control Thermostat