TROUBLESHOOTING (cont.)
PROBLEM
Spitting or excessive steaming
PROBABLE CAUSE
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
REMEDY
Inspect tank assembly for excessive lime deposits. Delime as required.
2. | Control Thermostat | Refer to Service - Control Thermo- |
|
| stat for testing procedures. See |
|
| page 20 |
1. | Funnel Tip | The brew funnel should be cleaned |
|
| thoroughly before each brew cycle |
|
| to lessen the chance of tea leaf par- |
|
| ticles clogging the |
Dripping from sprayhead
1.Syphon System
2.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
Water flows into tank continuously (ON/OFF Switch "ON")
Water flows into tank continuously (ON/OFF Switch "OFF")
3. | Brew Solenoid Valve | Refer to Service - Brew Solenoid |
|
| Valve for testing procedures. See |
|
| page 16 |
1. | Brew Timer | Refer to Service - Brew Timer for |
|
| testing procedures. See page 16 or |
|
| 18 |
1. | Brew Solenoid Valve | Refer to Service - Brew Solenoid |
|
| Valve for testing procedures. See |
|
| page 16 |
Page 12 | 10225 | 031804 |
|
|