SERVICE (cont.) |
| If continuity is present as described, reconnect the | ||||
DILUTION TIMER |
| |||||
| wires to terminals TL3, TL4, & TL5 of the timer board | |||||
|
|
| ||||
|
|
| and proceed to #5. |
|
| |
|
|
| If continuity is not present as described, refer to the | |||
|
|
| Wiring Diagrams and check the wiring harness. |
| ||
|
|
| 5. With a voltmeter, check the voltage across termi- | |||
|
|
| nals TL1 and TL4 when the ON/OFF switch is in | |||
|
|
| the "ON" position and the start switch is momen- | |||
|
|
| tarily placed in the lower position. Connect the | |||
|
|
| brewer to the power source. After a delay of ap- | |||
|
|
| proximately three minutes, the indication must be: | |||
|
|
| a) 120 volts ac for two wire 120 volt models for | |||
|
|
| approximately one minute and then return to its | |||
|
|
| previous indication. |
|
| |
|
|
| b) 240 volts ac for two wire 240 volt models for | |||
|
|
| approximately one minute and then return to its | |||
|
|
| previous indication. |
|
| |
|
|
| c) 100 volts ac for two wire 100 volt models for | |||
|
| P1276.40 | approximately one minute and then return to its | |||
| FIG. 12 DILUTION TIMER | previous indication. |
|
| ||
|
|
|
| |||
Location: |
| 6. Disconnect the brewer from the power source. | ||||
|
|
|
| |||
| The dilution timer is located inside the hood on the | If voltage is present as described, the timer is operat- | ||||
right side. It consists of the dial plate with two dials | ||||||
ing properly. Adjust the timer dials as required. |
| |||||
and circuit board. |
|
| ||||
| If voltage is not present as described, replace the timer. | |||||
|
|
| ||||
Test Procedure: |
| Removal and Replacement: |
| |||
1. | Disconnect the brewer from the power source and |
| ||||
1. Remove all wires from the timer. |
| |||||
| remove the wires from terminals TL3, TL4, & TL5 |
| ||||
| 2. Remove the circuit board and dial plate from the | |||||
| of the timer and rotate both dials fully counter- | |||||
| brackets. |
|
| |||
| clockwise. |
|
|
| ||
|
| 4. Install the new dial plate and circuit board to the | ||||
2. With a voltmeter, check the voltage across termi- | ||||||
brackets. |
|
| ||||
| nals TL1 and TL2 when the ON/OFF switch is in |
|
| |||
| 5. Refer to Fig. 13 when reconnecting the wires. | |||||
| the "ON" position. Connect the brewer to the power | |||||
| 6. Adjust the timer dials as required. |
| ||||
| source. The indication must be: |
|
| |||
|
|
|
|
| ||
| a) 120 volts ac for two wire 120 volt models. |
|
|
| ||
| b) 240 volts ac for two wire 240 volt models. | WHI/BLU to Dilution Solenoid | GRN to Start Switch |
| ||
| c) 100 volts ac for two wire 100 volt models. | RED/BLK to Start Switch |
|
| ||
3. | Disconnect the brewer from the power source. | WHI to Brew Timer (100V & |
|
| ||
|
|
| 120V Models) |
|
| |
If voltage is present as described, proceed to #4. | RED to Brew Timer (240V |
|
| |||
Models) |
|
| ||||
If voltage is not present as described, refer to the Wir- | WHI/VIO to ON/OFF Switch |
|
| |||
ing Diagrams and check the wiring harness. |
| GRY to Selector Switch | PNK to Selector Switch | |||
|
|
| ||||
4. | Check for continuity across the green and red/ | (Half Batch Option Only) | (Half Batch Option Only) | |||
PNK to Selector Switch | GRY to Selector Switch | |||||
| black wires when the start switch is held in the | (Half Batch Option Only) | (Half Batch Option Only) | |||
|
|
|
| |||
| lower position. |
| FIG. 13 DILUTION TIMER TERMINALS | P1281 | ||
|
|
|
| |||
|
| Page 22 | 10225 | 071500 | ||
|
|
|
|