TROUBLESHOOTING (cont.) |
|
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
|
Beverage overflows dispenser | 1. Dispenser | The dispenser must be completely | |
|
| empty before starting a brew cycle. | |
| 2. Brew Timer | Refer to Service - Brew Timer for | |
|
| testing procedures. See page | 17 |
|
| or 18 |
|
| 3. Brew Solenoid Valve | Remove the Brew Solenoid Valve | |
|
| and clean any obstruction. Rebuild | |
|
| or replace the valve if necessary. | |
|
| See page 16 |
|
| 4. Dilution Timer | Refer to Service - Dilution Timer for | |
|
| testing procedures. See page 22 | |
| 5. Dilution Solenoid Valve | Refer to Service - Dilution Solenoid | |
|
| Valve for testing procedures. See | |
|
| page 21 |
|
Weak beverage | 1. Filter Type | BUNN¨ paper filters must be used | |
|
| for proper extraction. |
|
| 2. Tea | A sufficient quantity of fresh, loose | |
|
| tea leaves should be used for proper | |
|
| extraction. |
|
| 3. Sprayhead | A clean stainless steel | |
|
| must be used for proper extrac- | |
|
| tion. |
|
| 4. Funnel Loading | The BUNN¨ paper filter must be | |
|
| centered in the funnel and the bed | |
|
| of tea leaves leveled by gentle shak- | |
|
| ing. |
|
| 5. Water Temperature | Place an empty funnel on an empty | |
|
| dispenser beneath the sprayhead. | |
|
| Initiate a brew cycle and check the | |
|
| water temperature immediately be- | |
|
| low the sprayhead with a thermom- | |
|
| eter. The reading should not be less | |
|
| than 200°F (93°C). Adjust the con- | |
|
| trol thermostat to increase the wa- | |
|
| ter temperature. Replace if neces- | |
|
| sary. |
|
| Page 13 | 10225 | 031804 |
|
|
|