TROUBLESHOOTING (cont.)
PROBLEM
Funnels overflow (cont.)
Coffee reservoir overflows
Brewer is making unusal noises
PROBABLE CAUSE
3.Pump - Flow Rate
4.Soft Water
1.Coffee reservoir not completely empty befor a brew cycle was started.
2.Timer
3.Pump - Flow Rate
1.Solenoid Valve
2.Plumbing lines
3.Water supply
4.Tank Heater(s)
REMEDY
Check pump flow rate with a watch. Pump flow rate should be approxi- mately 24 ounces in 15 seconds. Be sure pump assembly is free of any obstructions.
When using a water softener, a coarse grind of coffee may be preferred. If required, a bypass system is available as an optional feature.
Be sure coffee reservoir is empty before brew cycle is started.
Refer to Service
Check pump flow rate with a watch. Pump flow rate should be approxi- mately 24 ounces in 15 seconds. Be sure pump assembly is free of any obstructions.
The nut on the solenoid must be tight or it will vibrate during operation.
Plumbing lines should not be rest- ing on the counter top.
(A)The brewer must be connected to a cold water line.
(B)Water pressure to the brewer must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the pressure to approxi- mately 50 psi (345 kPa).
Remove and clean lime off the tank heater. See page 30
Page 12 | 10060 | 080900 |
|