Bunn U3A service manual SERVICE cont START SWITCH BREW, Start Switch Brew

Models: U3A U3

1 42
Download 42 pages 23.98 Kb
Page 29
Image 29
SERVICE (cont.)

SERVICE (cont.)

START SWITCH (BREW)

FIG. 24 START SWITCH (BREW)

P1317.30

 

Location:

 

The brew start switch is located on the upper right side of the brewer component housing.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Remove the wires from the start switch termi- nals.

3.Check for continuity across the switch terminals when the switch is held in the lower position. Continuity must not be present when the switch is in the upper position.

If continuity is present as described, reconnect the wires the switch is operating properly.

If continuity is not present as described, replace the switch.

Removal and Replacement:

1.Remove the wires from the switch terminals.

2.Compress the clips on the back side of the switch mounting bracket and gently push the through the opening.

3.Push the new switch into the opening and spread the clips to hold switch in the mounting bracket.

4.Refer to Fig. 25 and reconnect the wires.

BLU to Brew Timer or

Brew Lockout Relay

BLK from ON/OFF Switch FIG. 24 START SWITCH (BREW)

ALL MODELS EXCEPT 230V - CE MODELS

BLU to Brew Timer or

Brew Lockout Relay

RED from ON/OFF

Switch

230V - CE MODELS

P1743

FIG.25 BREW START SWITCH TERMINALS

Page 29

10060

031599

 

Page 29
Image 29
Bunn U3A service manual SERVICE cont START SWITCH BREW, Start Switch Brew