ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in Initial
L2 RED |
| |
WHITE | 120V A.C. | |
208 OR | ||
| ||
NEUTRAL | 240V A.C. | |
120V A.C. | ||
L1 BLACK | ||
|
P1841
RED
L2
BLUE
L3
BLACK
L1
GREEN
208V OR 240V
380V OR 440V
208V OR 240V 380V OR 440V
208V OR 240V
380V OR 440V
GREEN
P1843
U3 & U38 requires
U333 & U3833 requires
BLACK L1 |
|
RED | 230V A.C. |
| |
L2 |
|
GREEN |
| GREEN | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P1842
WHITE
(NEUTRAL) N
RED L2 BLUE L3 BLACK L1
GREEN
|
|
|
|
|
|
|
|
|
|
|
|
|
| L1, L2, L3, are the 3 phases | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| V1 = Phase to phase voltage, | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| between any 2 phases. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| V2 = Phase to neutral voltage, | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| any phase to neutral. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| GREEN |
|
|
|
| ||||||||
|
|
|
|
| SYSTEM |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| VOLTAGE | V1 | V2 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| P1844 | 208 | 208 | 120 |
| ||||||||||
|
|
| 240 | 240 | 139 |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 380 | 380 | 220 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 440 | 440 | 254 |
|
U3A models require
U3833 requires
380 volts ac or 440 volts ac, 30 amp, three phase, 50 Hz. Proceed as follows:
ELECTRICAL INSTALLATION INSTRUCTIONS
NOTE: Electrical source should have a circuit breaker between the brewer and the main supply which breaks all poles with a contact separation of at least 3 mm.
1.An electrician must provide electrical service as specified.
2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3.Before electrically connecting the brewer, remove the front cupola cover (some models have the thermostat knob on the outside of the cover) and rotate the thermostat knob fully counterclockwise to the "OFF" position. Keep this knob in the "OFF" position until performing the Initial Setup.
4.Electrical service is connected at the upper rear of the single service and scrambler brewers using a junc- tion box. On double service brewers the rear decorative channel must be removed for access to the terminal block.
5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Re- place all panels.
6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Setup.
NOTE: Schematic wiring diagrams are included in this manual.